The XPARTCO DC47-00016A is an aftermarket replacement thermal fuse for Samsung dryers. Mounted on the blower housing near the heat source, this fuse is a one-time safety device: as long as the dryer stays within its normal operating temperature, it does nothing at all, but the instant internal temperatures climb dangerously high — almost always from restricted airflow — the fuse permanently opens the circuit and cuts power to the dryer. That's why a blown thermal fuse produces such a specific symptom: the dryer won't start at all, with no lights, no tumble, and no response, even though the outlet has power.
This fuse terminates in 1/4" male spade connectors for a direct plug-in fit. Unlike a thermostat, a thermal fuse cannot be reset once it blows — it must be replaced. Critically, a blown thermal fuse is almost always a symptom rather than a random failure: restricted exhaust venting is the leading cause, since trapped heat is exactly what the fuse is designed to react to. A failing thermistor can also cause repeated fuse blows, since the two work together to regulate temperature. It directly replaces 2068545, AP4201894, AP4201899, PS4205213, EAP4205213, PS2038378, PS2038533, and 35001087.
Quick Answer
The XPARTCO DC47-00016A Dryer Thermal Fuse fixes Samsung dryers that won't start at all — no lights, no tumble, no response to any button — after overheating from restricted airflow. 1/4" male spade terminals. Replaces 2068545, AP4201894, AP4201899, PS4205213, EAP4205213, PS2038378, PS2038533, 35001087. Always inspect and clean the dryer venting when replacing this fuse — a blown fuse is a symptom of restricted airflow, and installing a new fuse without fixing the vent will likely blow it again.
Common Problems This Part Fixes
- Dryer won't start at all — no lights, no tumble, no response to any button
- Dryer that stopped working suddenly, especially after a load felt unusually hot
- Dryer runs a short time then shuts off completely and won't restart
- Repeated blown fuses on a dryer with a known venting or airflow restriction
- Clothes coming out extremely hot right before the dryer stopped working
- Dryer that recently smelled like burning or overheating before failing
- Continuity test shows an open circuit across the old fuse
Cross Reference Information
Part numbers can change over a product's lifecycle as manufacturers update designs or release new appliance models. For your convenience, we've included any known superseded, alternate, or cross-reference part numbers that match this item.
Replaces Part Numbers
This dryer thermal fuse directly replaces the following OEM and cross-reference part numbers:
DC47-00016A, L0016A, AP4201894, PS4205213, AP6008681, EAP4205213, OEM12605691, EAP11741821, ASM868996, PD00005341, PD00003747, PS11741821, 35001087, WP35001087.
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermal fuse is compatible with select Samsung dryers, and also fits select LG and Kenmore dryers built on a compatible platform, including model numbers such as:
- DV209AEW/XAA, DV210AEW, DV210AEW/XAA
- DV218AEB/XAA, DV218AEW/XAA, DV219AEW/XAA, DV220AEW, DV220AEW/XAA
- DV330AEW, DV350AEW/XAA, DV419AEW/XAA
Note: This fuse is commonly paired with a matching thermistor (DC32-00007A) and thermostat (DC96-00887A / DC47-00018A), and manufacturer guidance recommends replacing the thermistor at the same time as the fuse, since the two work together and a failing thermistor is a common cause of repeated fuse blows. Always verify your full model number before ordering. Contact our support team with your model number if you're unsure.
Key Features
- Aftermarket replacement thermal fuse — one-time safety device that cuts power if the dryer overheats
- Resolves "won't start at all," "stopped working suddenly," and "clothes came out extremely hot before it died" symptoms caused by a blown fuse
- 1/4" male spade terminal connectors for a direct plug-in electrical fit
- Mounts to the blower housing near the heat source
- Replaces 2068545, AP4201894, AP4201899, PS4205213, EAP4205213, PS2038378, PS2038533, and 35001087
- Compatible with select Samsung, LG, and Kenmore dryers
- Aftermarket replacement built to OEM-equivalent quality standards
- Quick, simple repair — no special tools required beyond a basic screwdriver
Product Specifications
| Part Number | DC47-00016A |
| OEM Part Number | DC47-00016A |
| Part Type | Dryer Thermal Fuse (Thermal Cut-Off) |
| Condition | Aftermarket Replacement |
| Location | Blower housing, near the heat source |
| Terminals | 1/4" male spade connectors |
| Resettable | No — one-time use, must be replaced once blown |
| Companion Parts | Thermistor DC32-00007A, thermostat DC96-00887A / DC47-00018A |
| Quantity | 1 thermal fuse |
| Compatible Brands | Samsung, LG, Kenmore |
Installation Notes
Frequently Asked Questions
I replaced the fuse and it blew again. What's going on?
This is a strong sign that the underlying cause — almost always restricted airflow — was never addressed. Thermal fuses don't fail from age; they blow because the dryer overheated. If a new fuse keeps blowing, thoroughly inspect and clean the entire exhaust path from the lint trap housing to the outside vent hood, checking for lint buildup, crushed or kinked ductwork, or a vent run that's too long. If airflow checks out and the fuse still blows, have the thermistor and thermostat checked as well, since a failing thermistor can also trigger repeated fuse blows.
Can I just reset the thermal fuse instead of replacing it?
No. Unlike a thermostat, a thermal fuse is a one-time safety device — once it blows, its internal circuit is permanently broken and it cannot be reset or repaired. Replacement is the only option.
Should I replace the thermistor at the same time as the fuse?
It's worth strongly considering, and it's a common manufacturer recommendation. The thermistor and thermal fuse work together to manage temperature, and a failing thermistor can cause the dryer to run hotter than it should, leading directly to repeated fuse blows. Replacing both together, especially if your dryer has blown this fuse more than once, addresses the more likely root cause rather than just the symptom.
My clothes came out extremely hot right before the dryer died. Is that related?
Yes, this is a classic warning sign. Clothes coming out unusually hot indicates the dryer was already running hotter than normal, which is exactly the condition that leads to a blown thermal fuse. If you noticed this before the dryer stopped working, it strongly points to a ventilation or airflow problem that should be fully addressed before running the dryer again.
Is this an OEM or aftermarket part?
This is an aftermarket replacement part built to OEM-equivalent quality standards. It is not a genuine Samsung OEM part, but is manufactured to match the electrical specifications, spade terminal connections, and mounting configuration of the original DC47-00016A thermal fuse used in compatible Samsung, LG, and Kenmore dryers.