XPARTCO 280148 Dryer Thermostat Set
This XPARTCO 280148 is an aftermarket thermal fuse and high-limit thermostat set for Whirlpool electric dryers, and it also fits select Kenmore, Maytag, Amana, Roper, Estate, Crosley, Admiral, KitchenAid, and Norge models. The set pairs two safety parts. The 8557403 high-limit thermostat watches the temperature, cuts power to the heating element if it overheats, and resets itself once the dryer cools. The 8318314 thermal fuse is a one-time backup that permanently opens the circuit if temperatures climb high enough that the thermostat alone doesn't prevent an overheat.
The two parts are sold together because they protect the same circuit, respond to the same overheating conditions (most often restricted exhaust venting), and commonly fail around the same time. Signs of trouble include a dryer that doesn't heat, takes longer than normal to dry a load, or overheats before shutting down. It directly replaces 280148VP, 1175772, AP3874047, PS991443, EAP991443, and 314634.
Quick Answer
Choose the XPARTCO 280148 Dryer Thermostat Set for Whirlpool, Kenmore, Maytag, Amana, Roper, Estate, Crosley, Admiral, KitchenAid, and Norge electric dryers with no heat, drying that takes too long, or overheating before shutdown. Includes the 8557403 high-limit thermostat (auto-resetting) and 8318314 thermal fuse (one-time). Replaces 280148VP, 1175772, AP3874047, PS991443, EAP991443, 314634. Always inspect and clean the exhaust venting when replacing this set — a blown thermal fuse is a symptom of restricted airflow, and skipping the vent check leads to repeat failures.
What's In The Set
| Component | Type | Function |
|---|---|---|
| 8557403 High-Limit Thermostat | Auto-resetting | Cuts power to the heating element if temperature exceeds safe limits, resets automatically once the dryer cools. |
| 8318314 Thermal Fuse | One-time, non-resettable | Backup safety device — permanently opens the circuit if temperature exceeds safe limits. Must be replaced once blown. |
Common Problems This Set Fixes
- Dryer runs but produces no heat at all
- Dryer won't start at all — no lights, no tumble, no response
- Drying takes noticeably longer than it used to
- Dryer overheating before shutting down
- Dryer that stopped working suddenly after running unusually hot
- Repeated thermal fuse failures on a dryer with a known venting issue
Cross Reference Information
Part numbers can change over a product's lifecycle as manufacturers update designs or release new appliance models. For your convenience, we've included any known superseded, alternate, or cross-reference part numbers that match this item.
Replaces Part Numbers
This dryer thermostat set directly replaces the following OEM and cross-reference part numbers:
280148, 1175772, 280148VP, PD00002627, FIX991443, EAP991443, AH991443, AP3874047, AWP39427, EA991443, PS991443, 8318314, WP8557403, 8557403, 1180102, AP6013164, AWP48681, PD00003588, PS11746386
If your part number is not listed above, contact our support team before ordering and we will verify compatibility.
Compatibility
This thermostat set is compatible with select Whirlpool electric dryers, and also fits select Kenmore, Maytag, Amana, Roper, Estate, Crosley, Admiral, KitchenAid, and Norge dryers built on the Whirlpool platform, including model numbers such as:
- 7MWED5620HW0, 7MWED5620HW1, 7MWED6613HC0, 7MWED6613HC1, 7MWED6613HW0, 7MWED6613HW1
- MED5500FC1, MED5500FC2, MED5500FW1, MED5500FW2
- MED5630HC0, MED5630HC1, MED5630HC2, MED5630HW0, MED5630HW1, MED5630HW2
- MED6000XG0, MED6000XG1, MED6000XG2, MED6000XR0, MED6000XR1, MED6000XW0, MED6000XW1, MED6000XW2
- MED6630HC0, MED6630HC1, MED6630HC2, MED6630HW0, MED6630HW1, MED6630HW2
- MED7000XG0, MED7000XG1, MED7000XR0, MED7000XR1, MED7000XW0, MED7000XW1, MED7000XW2
- MED7230HC0, MED7230HC1, MED7230HC2, MED7230HC3, MED7230HW0, MED7230HW1, MED7230HW2, MED7230HW3
- MED8200FC1, MED8200FC2, MED8200FW1, MED8200FW2
Note: Always verify your full model number before ordering, since Whirlpool uses several different thermostat and fuse designs across its dryer lineup. This set is commonly purchased alongside heating element WP8544771. Contact our support team with your model number if you're unsure.
Key Features
- 2-piece set: 8557403 auto-resetting high-limit thermostat and 8318314 one-time thermal fuse
- Resolves "no heat," "won't start at all," "takes too long to dry," and "overheating" symptoms
- Addresses two overheat-protection thresholds in the same circuit at once
- Commonly purchased alongside heating element WP8544771
- No special tools required for installation
- Replaces 280148VP, 1175772, AP3874047, PS991443, EAP991443, and 314634
- Compatible with Whirlpool, Kenmore, Maytag, Amana, Roper, Estate, Crosley, Admiral, KitchenAid, and Norge electric dryers
- Aftermarket replacement built to OEM-equivalent quality standards
Product Specifications
| Set Part Number | 280148 |
| OEM Part Number | 280148 |
| Set Contents | 1x High-Limit Thermostat (8557403), 1x Thermal Fuse (8318314) |
| Condition | Aftermarket Replacement |
| Application | Whirlpool Electric Dryers |
| High-Limit Thermostat Type | Automatically resetting |
| Thermal Fuse Type | One-time use, non-resettable |
| Companion Heating Element | WP8544771 (commonly used together) |
| Repair Difficulty | Easy to Moderate — no special tools required |
| Compatible Brands | Whirlpool, Kenmore, Maytag, Amana, Roper, Estate, Crosley, Admiral, KitchenAid, Norge |
Installation Notes
Frequently Asked Questions
Why replace both the thermostat and the fuse together instead of just the one that failed?
The two parts guard the same circuit at different thresholds and usually fail for the same underlying reason. When the high-limit thermostat isn't regulating temperature properly, the thermal fuse frequently blows as the backup safety measure. Swapping only one risks the other failing soon afterward, which is why they are sold and serviced together as a set.
I replaced this set and the dryer failed again. What should I check?
This is a strong sign the underlying cause — almost always restricted airflow — was never addressed. Thoroughly inspect and clean the entire exhaust path from the lint trap housing to the outside vent hood, checking for lint buildup, crushed or kinked ductwork, or a vent run that's too long. Failing to correct a venting issue will cause repetitive failures of this set even when it's brand new.
Should I replace the heating element at the same time?
It's worth considering if your dryer's heating element (commonly WP8544771 on compatible models) is original and has been running alongside a failing thermostat, since sustained overheating can stress the element as well. It's not required, but since you'll already have the panel open for this repair, it's a reasonable time to inspect the element for visible damage.
Is this an OEM or aftermarket part?
This is an aftermarket replacement part built to OEM-equivalent quality standards. It is not a genuine Whirlpool OEM part, but is manufactured to match the temperature thresholds and mounting configuration of the original 280148 high-limit thermostat and thermal fuse set used in compatible Whirlpool, Kenmore, Maytag, Amana, Roper, and related electric dryers.
Shop With Confidence
Express Parts Direct is a U.S.-based appliance parts retailer offering genuine OEM and high-quality replacement parts for all major brands, with fast shipping from our U.S. warehouse. Our team can help verify compatibility before you buy.
Have a question?