- Sku: W11645245
W11645245 Refrigerator Genuine OEM Dual Water Valve
FREE SHIPPING TO ALL 48 CONTIGUOUS STATES
Free standard shipping at checkout.
CHECK YOUR MODEL COMPATIBILITY
Enter your appliance model number to check if this part is listed as compatible.
Need help finding your model number?
W11645245 Refrigerator Dual Water Inlet Valve — Genuine OEM
Product Description
When a Whirlpool side-by-side refrigerator stops making ice, stops dispensing water, or both, the dual water inlet valve is a common suspect — but it is not always the cause. Before ordering a replacement valve, work through the supply chain from the wall to the valve. First, confirm the household water supply valve (typically under the kitchen sink or in the basement) is fully open. Check the water supply line running to the rear of the refrigerator for kinks — a kinked copper or braided line can reduce pressure enough to prevent the valve from opening. Next, check the refrigerator water filter. A clogged or overdue filter restricts water flow to both the ice maker and the dispenser. Replace the filter if it has been in service more than six months or if water flow improves when you bypass the filter temporarily.
If the supply is open, the line is not kinked, and the filter is fresh, the problem is at or downstream of the valve. The W11645245 has two solenoids — one for the ice maker, one for the water dispenser. Each can fail independently. If the dispenser works but the ice maker gets no water, the fault could be the ice maker solenoid in the valve, but it could also be a frozen fill tube between the valve and the ice maker mold, or a failed ice maker module that is not calling for water. If both the ice maker and dispenser are dead, low household water pressure (below approximately 20 psi), a failed control board, or a wiring fault are possible upstream causes. If water leaks from the valve area when the refrigerator is not calling for water, the internal diaphragm is likely stuck open — a mechanical valve failure that requires replacement.
Quick Answer
Is Your Refrigerator Water Valve the Problem?
If you've confirmed the household supply valve is open, the supply line is not kinked, and the water filter is fresh — and your side-by-side refrigerator still won't dispense water, won't make ice, produces weak flow, or leaks from the valve area at the bottom rear — the dual water inlet valve is the most likely cause. To help narrow it down: if the dispenser works but ice production has stopped, check for a frozen fill tube or failed ice maker module before condemning the valve. If both ice and water are completely dead, verify household water pressure is adequate. The W11645245 is the genuine OEM replacement for select Whirlpool-built side-by-side refrigerators.
Common Symptoms
- Ice maker stops producing ice despite adequate water supply and fresh filter
- Water dispenser produces no water or very weak, slow flow
- Both ice maker and water dispenser are non-functional
- Water leaks from the valve area at the bottom rear of the refrigerator
- Loud buzzing from the rear lower area with reduced or no water delivery
Replaces Part Numbers
The W11645245 is Whirlpool's current production number for the dual water inlet valve on select side-by-side refrigerators. It is the latest revision in a line of superseded valve assemblies and replaces the following part and catalog numbers.
Compatibility & Model Cross Reference
This genuine OEM valve fits Whirlpool-manufactured side-by-side refrigerators sold under multiple brands. Confirm your model number before ordering.
Whirlpool: WRS315SDHM08, WRS325SDHW01, WRS335SDHW06, WRS342FIAW00
Amana: ASI2575GRB08, ASI2175GRW09
Kenmore: 10650049710, 10651119710
This is a partial list of sample models. Kenmore refrigerators with a 106-prefix model number are commonly built by Whirlpool and may use the same valve platform. Always confirm your full model number before ordering.
Key Features
- Genuine OEM Whirlpool dual water inlet valve — independent ice maker and dispenser ports
- Two solenoid coils operate independently for separate ice maker and dispenser control
- Direct replacement for superseded valve revisions W11446818, W11546685, and W11563296
- Mounts behind the rear lower access panel — standard screwdriver and pliers installation
- Connects to household water supply and routes water to ice maker and dispenser lines
- Manufactured in Mexico — genuine Whirlpool factory part
Product Specifications
| Part Number | W11645245 |
| Condition | New |
| Brand | Whirlpool |
| Part Type | Dual Water Inlet Valve (Ice Maker & Dispenser) |
| Appliance Type | Side-by-Side Refrigerator |
| Number of Solenoids | 2 (dual coil) |
| Supersedes | W11446818, W11546685, W11563296 |
| Country of Origin | Mexico |
Installation & Safety Notes
Unplug the refrigerator and shut off the household water supply valve before disconnecting any water lines or wiring. Safely store perishable food that could deteriorate while the power is off. Have towels or a shallow pan ready — residual water will drain from the supply line and valve ports when disconnected. The valve is behind the rear lower access panel. After installing the new valve, turn the supply valve on slowly and inspect every connection for leaks before restoring power. Allow 24 hours for the ice maker to begin producing ice after the new valve is installed and the water supply is restored.
Frequently Asked Questions
- How do I tell if the problem is the valve or a frozen fill tube?
- If the ice maker has stopped but the water dispenser still works, a frozen fill tube is one of the most common causes. The fill tube is a small plastic tube that runs from the valve outlet to the ice maker mold — it passes through the freezer wall and can freeze solid if the freezer temperature is set too low or if the tube's insulation or heater has failed. To check, locate the fill tube opening above the ice maker mold and try directing warm air at it with a hair dryer. If water starts flowing to the mold after thawing, the fill tube was the problem, not the valve. If the tube is clear and the ice maker module is cycling but no water reaches the mold, the ice maker solenoid in the valve is the likely failure.
- Can I test the solenoid coils with a multimeter?
- Yes. Unplug the refrigerator, remove the rear lower access panel, and disconnect the wire harness from the valve. Set your multimeter to ohms and test across the two terminals on each solenoid coil. A working coil will show measurable resistance. An open-circuit reading (OL or infinity) means the coil wire is broken and that solenoid cannot be energized — the valve needs replacement. A very low reading near zero indicates a shorted coil, which also requires replacement. If both coils show resistance within normal range but the valve still doesn't deliver water, the problem may be upstream — verify household water pressure and check for a failed control board signal. Refer to your model's service manual for the manufacturer-specified coil resistance range.
- My water dispenser flow has gotten progressively weaker. Is that the valve?
- Possibly, but check the water filter first. A filter that is nearing the end of its service life progressively restricts flow — this is the single most common cause of gradually weakening dispenser output. Replace the filter and test. If flow does not improve with a fresh filter, the problem is likely mineral buildup inside the valve restricting the dispenser port. Hard water deposits accumulate over time inside the valve passages and cannot be cleaned out — the valve must be replaced. A kinked supply line can also reduce flow, so inspect the line running to the rear of the refrigerator as well.
- Both ice and water stopped at the same time. Is it still the valve?
- When both functions fail simultaneously, the valve is possible but not the most likely first cause. Both solenoids failing at the same time is uncommon. More often, a simultaneous loss of both ice and water points to something upstream that affects both: the household supply valve was accidentally turned off, the supply line is kinked or frozen, the water filter is completely blocked, household water pressure dropped below the minimum required for the valve to open, or a wiring fault or failed control board is not sending voltage to either solenoid. Work through the supply chain from the wall to the valve before condemning the valve itself.
- Why does the valve leak only when the refrigerator is not calling for water?
- This is a classic sign of a worn diaphragm. When a solenoid is energized during normal operation, water pressure and the solenoid plunger hold the diaphragm in a stable open position. When the solenoid de-energizes, the diaphragm must seal entirely under spring pressure. If the rubber has hardened, cracked, or taken a permanent set from mineral deposits, it no longer seats tightly and water seeps through at a slow rate. You may notice water pooling under the refrigerator, the ice maker tray slowly overfilling, or a small puddle forming near the rear of the unit. This is a mechanical valve failure — the diaphragm is not serviceable and the valve must be replaced.
Have a question?

W11645245 Refrigerator Genuine OEM Dual Water Valve
Model Compatibility
Search your appliance model number below. Supports partial or full model search.
🔍 Search Model Number
Type your full or partial model number above to instantly check if this part fits your appliance.
| Model Number | Manufacturer | Appliance Type |
|---|
⚠️ This is a partial compatibility list. Always verify your appliance model number before ordering. Contact our support team if you’re unsure.