{"product_id":"w10909685-dryer-genuine-oem-thermal-fuse","title":"W10909685 Dryer Genuine OEM Thermal Fuse","description":"\u003cstyle\u003e\n.epd-wrap{font-family:-apple-system,BlinkMacSystemFont,\"Segoe UI\",Roboto,sans-serif;max-width:800px;margin:0 auto;color:#1e293b;line-height:1.7;font-size:16px !important}\n.epd-wrap h2{font-size:22px !important;font-weight:800;color:#1e293b;margin:28px 0 12px;letter-spacing:-0.01em}\n.epd-wrap h3{font-size:18px !important;font-weight:700;color:#1e293b;margin:24px 0 10px}\n.epd-wrap p{font-size:16px !important;margin:0 0 14px;color:#334155}\n.epd-qa{background:#eef2ff;border-radius:10px;padding:20px 24px;margin:20px 0}\n.epd-qa-label{font-size:10px !important;font-weight:800;letter-spacing:0.1em;text-transform:uppercase;color:#4338ca;margin-bottom:6px}\n.epd-qa p{font-size:16px !important;color:#1e293b;margin:0}\n.epd-symptoms{margin:16px 0}\n.epd-symptoms li{font-size:16px !important;padding:6px 0;color:#334155;list-style:none;position:relative;padding-left:20px}\n.epd-symptoms li::before{content:\"✓\";color:#4338ca;font-weight:700;position:absolute;left:0}\n.epd-xref-box{background:#f8fafc;border:1px solid #e2e8f0;border-radius:8px;padding:16px 20px;margin:14px 0;font-family:\"SFMono-Regular\",Consolas,\"Liberation Mono\",monospace;font-size:14px !important;color:#334155;line-height:1.9}\n.epd-compat{background:#eef2ff;border-radius:10px;padding:20px 24px;margin:20px 0}\n.epd-compat-label{font-size:10px !important;font-weight:800;letter-spacing:0.1em;text-transform:uppercase;color:#4338ca;margin-bottom:8px}\n.epd-compat p{font-size:16px !important;color:#1e293b;margin:0 0 8px}\n.epd-features{margin:16px 0}\n.epd-features li{font-size:16px !important;padding:6px 0;color:#334155;list-style:none;position:relative;padding-left:20px}\n.epd-features li::before{content:\"✓\";color:#4338ca;font-weight:700;position:absolute;left:0}\n.epd-specs{width:100%;border-collapse:collapse;margin:16px 0}\n.epd-specs td{font-size:16px !important;padding:10px 14px;border-bottom:1px solid #e2e8f0}\n.epd-specs tr:nth-child(even){background:#f8fafc}\n.epd-specs td:first-child{font-weight:600;color:#1e293b;width:40%}\n.epd-specs td:last-child{color:#334155}\n.epd-warning{background:#fffbeb;border-left:4px solid #f59e0b;border-radius:0 8px 8px 0;padding:16px 20px;margin:20px 0;font-size:16px !important;color:#92400e}\n.epd-warning strong{font-size:16px !important}\n.epd-faq{margin:20px 0}\n.epd-faq-item{margin-bottom:16px}\n.epd-faq-item div:first-child{font-size:16px !important;font-weight:700;color:#1e293b;margin-bottom:4px}\n.epd-faq-item div:last-child{font-size:16px !important;color:#334155}\n.epd-badges{display:flex;flex-wrap:wrap;gap:8px;margin:20px 0}\n.epd-badge{display:inline-flex;align-items:center;background:#eef2ff;border:1px solid #c7d2fe;color:#4338ca;font-size:14px !important;font-weight:600;padding:6px 14px;border-radius:20px}\n\u003c\/style\u003e\n\u003cdiv class=\"epd-wrap\"\u003e\n\u003ch2\u003eW10909685 Dryer Thermal Fuse — Genuine OEM Whirlpool Part\u003c\/h2\u003e\n\n\u003cp\u003eThe W10909685 is a genuine OEM Whirlpool thermal fuse that serves as the dryer's last line of defense against overheating. When exhaust temperature at the blower housing exceeds 195°F, this non-resettable fuse opens the circuit permanently, cutting power to the heating system or motor depending on the dryer model. Testing is straightforward — a multimeter continuity check across the two terminals will read near zero ohms on a good fuse and open (no continuity) on a blown one.\u003c\/p\u003e\n\n\u003cp\u003eBefore replacing the fuse, it is critical to diagnose why it blew. A thermal fuse does not fail on its own — something drove the exhaust temperature past its rating. The root cause in the vast majority of cases is restricted venting: lint accumulation inside the exhaust duct, a crushed transition hose behind the dryer, or a blocked exterior vent hood. Less commonly, a seized blower wheel, a failed cycling thermostat that stopped regulating heat, or a shorted heating element can push temperatures past the fuse's threshold. Replacing the W10909685 without identifying and correcting the airflow problem guarantees the new fuse will blow again.\u003c\/p\u003e\n\n\u003cdiv class=\"epd-qa\"\u003e\n\u003cdiv class=\"epd-qa-label\"\u003eQUICK ANSWER\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#4338ca\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\" style=\"vertical-align:-2px;margin-right:4px\"\u003e\u003cpath d=\"M14.7 6.3a1 1 0 0 0 0 1.4l1.6 1.6a1 1 0 0 0 1.4 0l3.77-3.77a6 6 0 0 1-7.94 7.94l-6.91 6.91a2.12 2.12 0 0 1-3-3l6.91-6.91a6 6 0 0 1 7.94-7.94l-3.76 3.76z\"\u003e\u003c\/path\u003e\u003c\/svg\u003eWill This Fix Your Dryer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIf your dryer won't start, runs without heat, or shuts down mid-cycle, the thermal fuse is the first component to test. Set a multimeter to continuity and probe across the fuse terminals — no continuity means the fuse is blown and this genuine OEM W10909685 replacement will restore the circuit. If the fuse tests good (near zero ohms), the problem is elsewhere — the cycling thermostat, heating element, or igniter should be checked next.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eCommon Symptoms\u003c\/h3\u003e\n\u003cul class=\"epd-symptoms\"\u003e\n\u003cli\u003eDryer will not start — no response when cycle is selected\u003c\/li\u003e\n\u003cli\u003eDrum turns but heating element or gas burner does not activate\u003c\/li\u003e\n\u003cli\u003eDryer runs for several minutes then shuts off completely\u003c\/li\u003e\n\u003cli\u003eMultimeter reads open circuit (no continuity) across fuse terminals\u003c\/li\u003e\n\u003cli\u003eClothes come out damp after a full cycle\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCross Reference Information\u003c\/h3\u003e\n\u003cp\u003eThe W10909685 is the current Whirlpool part number for this thermal fuse and replaces all previous versions listed below. Any of these numbers found on an existing fuse or in a service manual confirms this is the correct replacement.\u003c\/p\u003e\n\u003cdiv class=\"epd-xref-box\"\u003e\nW10909685, 4461025, G4AP0506, TF 091C ACA2, W10693363, AP6034383, AWP42948, EAP11766766, FIX11766766, PD00036363, PS11766766\n\u003c\/div\u003e\n\n\u003cdiv class=\"epd-compat\"\u003e\n\u003cdiv class=\"epd-compat-label\"\u003eCOMPATIBILITY\u003c\/div\u003e\n\u003cp\u003eThis thermal fuse is designed for select Whirlpool, Maytag, Kenmore, Amana, Crosley, and Inglis dryers in both gas and electric configurations. Confirm your model number matches before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSample compatible models:\u003c\/strong\u003e WED5620HW1, WED8500DC1, WED5100HC0, MGD3500FW0, NED5800HW1, NGD5800HW1, MGD6630HC3, WGD8620HC0, WGD9620HC3, MED6230RHW\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"epd-features\"\u003e\n\u003cli\u003eGenuine OEM Whirlpool part — factory-spec thermal fuse\u003c\/li\u003e\n\u003cli\u003e195°F non-resettable cutoff prevents dryer overheating\u003c\/li\u003e\n\u003cli\u003eDirect blower housing mount — original connector and screw pattern\u003c\/li\u003e\n\u003cli\u003eWorks across gas and electric dryer platforms\u003c\/li\u003e\n\u003cli\u003eSupersedes previous part number W10693363\u003c\/li\u003e\n\u003cli\u003eTwo-terminal design for simple multimeter testing and installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable class=\"epd-specs\"\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eW10909685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOEM Part Number\u003c\/td\u003e\n\u003ctd\u003eW10909685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCondition\u003c\/td\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eWhirlpool\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Type\u003c\/td\u003e\n\u003ctd\u003eThermal Fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAppliance Type\u003c\/td\u003e\n\u003ctd\u003eDryer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Rating\u003c\/td\u003e\n\u003ctd\u003e195°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocation\u003c\/td\u003e\n\u003ctd\u003eBlower Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003ctd\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Brands\u003c\/td\u003e\n\u003ctd\u003eWhirlpool, Maytag, Kenmore, Amana, Crosley, Inglis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplaces\u003c\/td\u003e\n\u003ctd\u003eW10693363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003cdiv class=\"epd-warning\"\u003e\n\u003cstrong\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" viewbox=\"0 0 24 24\" fill=\"#854d0e\" stroke=\"none\" style=\"vertical-align:-2px;margin-right:4px\"\u003e\u003cpath d=\"M12 2L1 21h22L12 2zm0 4l7.53 13H4.47L12 6zm-1 5v4h2v-4h-2zm0 6v2h2v-2h-2z\"\u003e\u003c\/path\u003e\u003c\/svg\u003eSafety Warning\u003c\/strong\u003e\u003cbr\u003e\nNever bypass a thermal fuse by jumpering the terminals together. The fuse is a critical fire-prevention device. A blown thermal fuse is a symptom — the root cause is almost always restricted venting. Disconnect the exhaust duct and inspect the full run from the dryer cabinet to the exterior wall cap before installing the new fuse. Operating a dryer with restricted airflow risks lint ignition inside the duct or cabinet.\n\u003c\/div\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv class=\"epd-faq\"\u003e\n\u003cdiv class=\"epd-faq-item\"\u003e\n\u003cdiv\u003eHow do I test the thermal fuse with a multimeter?\u003c\/div\u003e\n\u003cdiv\u003eUnplug the dryer and locate the thermal fuse on the blower housing — it is a small white component with two wire terminals. Disconnect both wires and set your multimeter to the continuity or lowest ohms setting. Touch one probe to each terminal. A good fuse reads near zero ohms (you will hear a continuity beep). A blown fuse reads OL or shows no continuity. If the fuse is open, it must be replaced — there is no way to reset it.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"epd-faq-item\"\u003e\n\u003cdiv\u003eWhere exactly is the thermal fuse located?\u003c\/div\u003e\n\u003cdiv\u003eThe W10909685 mounts on the blower housing inside the dryer cabinet. On most Whirlpool and Maytag models, you reach it by removing the lower rear access panel. The fuse is a small white plastic component attached with a single mounting screw, with two flat wire connectors (spade terminals). It sits near the exhaust outlet where heated air exits the drum and enters the blower assembly.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"epd-faq-item\"\u003e\n\u003cdiv\u003eWhat is the difference between a thermal fuse and a cycling thermostat?\u003c\/div\u003e\n\u003cdiv\u003eA cycling thermostat opens and closes repeatedly during normal operation to regulate temperature — it is resettable and designed to cycle. A thermal fuse is a one-time safety device that blows permanently when temperature exceeds its rated limit (195°F for the W10909685). The cycling thermostat keeps the dryer in range; the thermal fuse shuts everything down when something goes wrong. Both are located on or near the blower housing but serve very different functions.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"epd-faq-item\"\u003e\n\u003cdiv\u003eWhat changed between W10693363 and W10909685?\u003c\/div\u003e\n\u003cdiv\u003eThe W10909685 is Whirlpool's current superseding part number for the W10693363. It is a direct functional replacement with the same 195°F rating, mounting points, and connector type. Whirlpool periodically updates part numbers during manufacturing revisions. If your dryer originally came with a W10693363, the W10909685 is the correct current replacement — the older number is no longer produced.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"epd-faq-item\"\u003e\n\u003cdiv\u003eCan I temporarily bypass the thermal fuse to test the dryer?\u003c\/div\u003e\n\u003cdiv\u003eNo — never bypass the thermal fuse under any circumstances. Jumpering the terminals removes the dryer's last line of defense against fire. If you suspect the fuse is the problem, test it with a multimeter to confirm. If it reads open, replace it with a new W10909685. There is no safe shortcut — the fuse exists specifically to prevent the dryer from operating when exhaust temperatures have exceeded safe limits.\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"epd-badges\"\u003e\n\u003cspan class=\"epd-badge\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#4338ca\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\" style=\"vertical-align:-2px;margin-right:3px\"\u003e\u003cpolyline points=\"20 6 9 17 4 12\"\u003e\u003c\/polyline\u003e\u003c\/svg\u003eGenuine OEM Part\u003c\/span\u003e\n\u003cspan class=\"epd-badge\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#4338ca\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" style=\"vertical-align:-2px;margin-right:3px\"\u003e\u003crect x=\"1\" y=\"3\" width=\"15\" height=\"13\"\u003e\u003c\/rect\u003e\u003cpolygon points=\"16 8 20 8 23 11 23 16 16 16 16 8\"\u003e\u003c\/polygon\u003e\u003ccircle cx=\"5.5\" cy=\"18.5\" r=\"2.5\"\u003e\u003c\/circle\u003e\u003ccircle cx=\"18.5\" cy=\"18.5\" r=\"2.5\"\u003e\u003c\/circle\u003e\u003c\/svg\u003eFast Shipping\u003c\/span\u003e\n\u003cspan class=\"epd-badge\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#4338ca\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" style=\"vertical-align:-2px;margin-right:3px\"\u003e\u003cpolyline points=\"21 8 21 21 3 21 3 8\"\u003e\u003c\/polyline\u003e\u003crect x=\"1\" y=\"3\" width=\"22\" height=\"5\"\u003e\u003c\/rect\u003e\u003cline x1=\"10\" y1=\"12\" x2=\"14\" y2=\"12\"\u003e\u003c\/line\u003e\u003c\/svg\u003eIn Stock\u003c\/span\u003e\n\u003cspan class=\"epd-badge\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"14\" height=\"14\" viewbox=\"0 0 24 24\" fill=\"none\" stroke=\"#4338ca\" stroke-width=\"2.5\" stroke-linecap=\"round\" stroke-linejoin=\"round\" style=\"vertical-align:-2px;margin-right:3px\"\u003e\u003cpath d=\"M14.7 6.3a1 1 0 0 0 0 1.4l1.6 1.6a1 1 0 0 0 1.4 0l3.77-3.77a6 6 0 0 1-7.94 7.94l-6.91 6.91a2.12 2.12 0 0 1-3-3l6.91-6.91a6 6 0 0 1 7.94-7.94l-3.76 3.76z\"\u003e\u003c\/path\u003e\u003c\/svg\u003e30–60 Min Install\u003c\/span\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Whirlpool","offers":[{"title":"Default Title","offer_id":67985583276085,"sku":"W10909685","price":53.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0285\/1107\/6405\/files\/W10909685_3_e88aa7e1-1135-4ce6-9078-45ad80cd1b6c.png?v=1794769585","url":"https:\/\/expresspartsdirect.com\/products\/w10909685-dryer-genuine-oem-thermal-fuse","provider":"Express Parts Direct","version":"1.0","type":"link"}